Uninterruptible Power & Data-Centre Distribution Solutions
KSTAR YDC9110S

KSTAR

KSTAR YDC9110S

KSTAR YDC9110S

Price on request
Capacity
10KVA
In / Out
1-Phase In / 1-Phase Out (220V:220V)
Series
YDC9100 Series
Weight (kg)
64
Dimensions
220*481*438

KSTAR YDC9110S — Specifications

Capacity 10KVA
Model KSTAR YDC9110S

KSTAR YDC9110S — Main Input Specifications

Rated Input Voltage 220Vac
Input Voltage Range 120Vac~276Vac
Number of Phases Single Phase, Three Wires
Input Frequency Range 50Hz: 45~55; 60Hz: 54~66 (50/60 Auto-adaptive)
Input Power Factor ≥0.99

KSTAR YDC9110S — Bypass Input Specifications

Rated Input Voltage 220/230/240
Input Voltage Range 220 Upper Limit: ±25% (Optional +10%, 15%, 20%); 230 Upper Limit: +20% (Optional +10%, 15%); 240 Upper Limit: +15% (Optional +10%); Lower Limit: -45% (Optional -20%, -30%)
Number of Phases Single Phase, Three Wires
Bypass Synchronization Range ±10%

KSTAR YDC9110S — Output Specifications

Voltage (Vac) 220/230/240±1%
Frequency Utility Mode: Synchronized with Input; When Utility Frequency Exceeds ±10% (Configurable: ±1%, ±2%, ±4%, ±5%), Output Frequency Is 50/60 (±0.1); Battery Mode: 50/60 (±0.1)
Waveform Sine Wave, THDV≤2% (100% Linear Load)
Transfer Time (ms) Utility Power ↔ Battery: 0; Utility Power ↔ Bypass: 0 (Synchronized)
Overall Efficiency ≥92%
Overload Capability ≤110%, 60min; ≤125%, 10min; ≤150%, 1min; >150%: Immediate Transfer to Bypass
Power Factor 0.8 (0.9 Optional)

KSTAR YDC9110S — Batteries

Battery Voltage ±96; ±108; ±120 (16/18/20 Batteries Optional)

KSTAR YDC9110S — Environment

Operating Temperature (℃) 0~40
Storage Temperature (℃) -25~55 (Excluding Batteries)
Relative Humidity 0~95% (Non-condensing)
Operating Altitude <1500m; Above 1500m, Derate in Accordance with GB/T3859.2
Noise (dB) ≤55

KSTAR YDC9110S — Other Features

Alarm Functions Alarms for Overload, Utility Power Abnormality, UPS Faults, Battery Undervoltage and Other Conditions
Protection Functions Alarms for Short Circuit, Overload, Overtemperature, Battery Undervoltage, Overvoltage/Undervoltage and Fan Faults
Communication Functions RS232 or USB; Optional SNMP Card, Relay Card and Parallel-operation Card

KSTAR YDC9110S — Mechanical Specifications

Dimensions (W*D*H), mm 250*502*616 (Including Casters) / 220*481*438
Net Weight (kg) 64
Applicable Standard YD/T 1095-2008

KSTAR YDC9110S — Warranty

Standard Warranty Repair or Replacement within 1 Year

Request a quote

Leave your details and an engineer will get back to you within one business day.

UPS Power Supply